Study of Optimal Performance of Taylor Fluid Viscous Dampers under Seismic Prone Zones
Daljeet Pal Singh , Omprakash Netula , Bilal Siddiqui
Abstract
Modern seismic design relies upon the inelastic response of structural members and systems to dissipate the energy imparted to a structure by an earthquake. The approach for controlling seismic damage in buildings and improving their seismic performance is by installing seismic dampers in place of structural elements. These dampers act like the hydraulic shock absorbers in cars and suspension in motorcycles where much of the sudden jerks are absorbed in the hydraulic fluids.
This research aims at a high rise building which is designed and seismic parameters are applied as per IS 1893:2016 Part-1 for different seismic zones on E-Tabs v18 Ultimate as per latest and modified IS Codal provisions. On observation it was found that there is a high maximum storey displacement occurring in the high rise building in vertical direction. Sometimes unknowingly earthquake strikes or fire or due to design error etc. the building collapses and the major structural member column fails which ultimately leads to failure of the structure.
We cannot stop these type of earthquakes and their causing collapses but we can draw some strategies in order to prevent the failure and save lives. So, the structural member column should be so strengthened so that it can resist the various loads like earthquake loads etc. in order to prevent its sudden failure. So, if the column does not fail there will be no sudden collapse of the beam and the mankind will be benefitted.
In order to make our structure safe, the Taylor Fluid Viscous Dampers are designed on the software E-Tabs v18 as per the parameters of Taylor Devices Inc. and then the dampers are applied at some specified locations and finally the most optimum location for the different seismic zones is found which resists the seismic energy and makes the structure safe and secure.
Thus the dampers reduce the energy available for shaking the building and this means that the building deforms less, so the chance of damage is reduced.
Full Text
PDF
References
A. Ras; N. Boumechra; Seismic energy dissipation study of linear fluid viscous dampers in steel structure design, Alexandria Engineering Journal, Elsevier, 55(3) 2821-2832 (2016).
Criteria for Earthquake Resistant Design of Structure General Provisions and Buildings, Bureau of Indian Standards, IS 1893-2016 Part-1, New Delhi, (2016).
D. Demetriou; N. Nikitas; K. D. Tsavdaridis; American Journal of Engineering and Applied Sciences, 8(4) 620-632 (2015).
H. R. Rahmani; C. Konke; Seismic Control of Tall Buildings Using Distributed Multiple Tuned Mass Dampers, Hindawi, Advances in Civil Engineering, 2019 (1) 1-19 (2019).
L. Xie; M. Cao; N. Funaki; H. Tang; S. Xue; Performance Study of an Eight-story Steel Building Equipped with Oil Dampers Damaged During the 2011 Great East Japan Earthquake, Journal of Asian Architecture and Building Engineering, 13(1) 181-188 (2015).
M. Khazaei; Investigation on Dynamics Nonlinear Analysis of Steel Frames with Steel Dampers, Procedia Engineering, Elsevier, 54(1) 401-412 (2013).
M. Mirtaheri; A. P. Zandi; S. S. Samadi; Hamid Rahmani Samani; Numerical and experimental study of hysteretic behavior of cylindrical friction dampers, Engineering Structures, Elsevier, 33(1) 3647-3656 (2011).
O. Netula; Study of Behavior of RCC Beam under Impact Loading and Effect of Hourglass Energy by Finite Element Analysis using ANSYS, International Journal of Engineering Research & Technology, 8(7) 127-134 (2019).
R. Aghlaraa; M. M.. Tahir; A passive metallic damper with replaceable steel bar components for earthquake protection of structures, Engineering Structures, Elsevier, 159(1) 185-197 (2018).
R.. V. Kartha; R. Ritzy; Tuned Liquid Damper to Control Earthquake Response in a Multi-Storied Building Frame, International Journal of Engineering Research and Applications, 5(8) 49-56 (2015).
S.R. Damodarasamy; S. Kavitha; Basics of Structural Dynamics and Aseismic Design, PHI Learning Private Limited, Delhi, (2018).
T. A. Sakr; Vibration control of buildings by using partial floor loads as multiple tuned mass dampers, HBRC Journal, Elsevier, 13(2) 133-144 (2015).
T. Belash; Dry Friction Dampers in Quake-proof Structures of Buildings, Procedia Engineering, Elsevier, 117(1) 402-408 (2015).
Z. Guenidia; M. Abdeddaima; A. Ounisa; M.K. Shrimalib; T.K. Datta; Control of Adjacent Buildings Using Shared Tuned Mass Damper, Procedia Engineering, Elsevier, 199(1) 1568-1573 (2017)